Ult freezer servicing and calibration

Annual service and calibration of our clients ult freezers, Labcold ult freezer and Haier ult freezer

Suez ultra pure water system service and calibration

A new Cryomed scientific client contacted ourselves when they were having pressure issues with their Suez laboratory ultra pure water system, quickly and efficiently diagnosing the fault due to consumables requiring to be replaced, full annual service and calibration of the system proceeded , PT8, PP8, ultra filter, pou filter , uv lamp and pre… Continue reading Suez ultra pure water system service and calibration

Annual service and calibration of Leica Cryostat

Annual service and calibration of our clients Leica Cryostat

Annual service and calibration of ULT Freeezers

Annual service of our clients

Sg/triple red/evoqua ultra pure water systems service and calibration

Annual service and calibration of our clients ultra pure laboratory water systems,consumables replaced including uv lamps, timers reset and calibrated using our ultra pure ukas accredited resistivity meter.

Sanyo ult freezer repair

Cryomed scientific welcomes A new client from Nottingham science park ,our engineer diagnosed and repaired the Sanyo ult freezer 2nd stage system being low in refrigerant ,within the same visit the Sanyo ultra low temperature -80 freezer was repaired and back down to set point of -80

Annual service and calibration of suez Purite laboratory water purification system

Annual service and calibration of our clients suez Purite laboratory water purification systems

Service and calibration freeze driers

Annual service and calibration of our clients freeze driers

IQ,OQ,PQ of our clients new Thermo co2 incubator

IQ,OQ,PQ validation of our clients new Thermo co2 incubator

Binder stability chambers

Repairs to our new clients Binder stability chambers

Annual service and calibration of our clients Labcold fridges and freezers

Rs biotech galaxy r+ co2 sensor replacement and calibration

Client advised that their rs biotech co2 incubator levels were irratic, diagnosing the fault as the co2 sensor failure ,this was removed and replaced on the same visit, calibrated and back operational the same day, happy client.

Binder ULT Freezer Annual service and calibration

Annual service and calibration of our clients Binder ultra low temperature -80 freezer

Ultra pure water system emergency callout Elga and triple red

Client called Cryomed when their Elga ultra pure water ringmain system failed, diagnosing the fault to be a faulty uv starting board issue, this was replaced at the same visit and back fully operational the same day. Client also had an issue with a triple red pure water system that was having an issue with… Continue reading Ultra pure water system emergency callout Elga and triple red

Sanyo ULT Freezer failure

Emergency callout this morning to one of our valuable clients, Sanyo -80 ult freezer , irratic temperature control was quickly diagnosed as faulty compressor control relays, these were replaced at the same visit and freezer back fully operational.

Eppendorf co2 incubator Galaxy R co2 sensor replacement

Service, calibration and co2 sensor replacement to our clients Eppendorf co2 incubator, replaced ,calibrated and back fully operational

Validation of heat block

Annual performance validation of our clients heat block over 7 points at 3 temperatures

Performance qualification on incubators

Performance qualification performed and executed for a new client of Cryomed scientific on their Thermo scientific Heather heated incubators

Annual service of ult freezers and incubators

Annual service and calibration of our clients -150 Panasonic ult freezer, Haier ult freezer, co2 incubator and various fridges and freezers

Purite laboratory water system repairs

IMG_8914 A couple of repairs on our clients Purite ultra pure water systems, back up and fully operational within 2 hours

Eppendorf co2 incubator control board replacement

Customer contacted Cryomed scientific when they had an issue with no co2 injecting into their Eppendorf co2 incubator, our engineer quickly diagnosed the control board was causing the issue, new control board was ordered and replaced and now back fully operational

Laboratory water ringmain service and calibration

Annual service and calibration of our clients ultra pure water ring main system, sanitisation of the ring main pipework and service of the Elga system with uv lamps

Annual -80 ULT Freezer service

Annual service and calibration to our clients 17 ultra low temperature freezers including Sanyo,Phcbi,New Brunswick , Haier and Panasonic

Untitled

Eppendorf co2 incubator calibration prior to being shipped to our client

ULT FREEZER SERVICING

Annual service to Panasonic -80 freezers , New Brunswick -80 freezers and Haier ultra low temperature freezers for our client

8 PHCBI CO2 INCUBATOR INSTALLATION

Installation of 8 new phcbi co2 incubators for our client, all completed and fully operational in one day.

Smart 2 pure laboratory water purification systems service and calibration

IMG_8639 Annual service and calibration to our clients laboratory water purification systems, all consumables supplied by Cryomed scientific who are now Purite approved supplier of consumables and new water purification systems, their barnstead smart 2 pure water purification system were serviced and calibrated , back fully operational in the same day with new consumables installed.

35 ULT -80 and -150 Freezer servicing

We welcome a new client to entrust their freezers and samples to Cryomed scientific ,they moved from their original service company to ourselves, we provide 24 hour emergency callout/365 days per year with cost saving incentives to clients who have over 10 freezers to service

Ringmain Laboratory ultra pure water system service, sanitisation and calibration

Annual service, sanitisation and calibration for our clients ringmain ultra pure water system, consumables supplied and installed by Cryomed scientific, calibration of clients resistivity meter and alarm system performed with UKAS resistivity meter, Work completed and back fully operational in one day.

Annual service, calibration and validation of Millipore ultra pure water system

Annual service, calibration and validation of our clients Millipore ultra pure laboratory water system, Cryomed supplied and replaced all consumables and calibrated the ultra pure water to 18.2 megaohms

Panasonic -150 chest freezer 2nd stage system refrigerant leak

IMG_7443IMG_7443 Refrigerant Leak on the 2nd stage of a Panasonic -150 ULT freezer model MDF-C2156VAN

Beckman centrifuge refrigeration system repair

IMG_7290

BOOST PUMP REPLACEMENT TO SUEZ WATER PURIFICATION SYSTEM

Removal and replacement of boost pump from our clients pure water Suez laboratory water system after our engineers recent pump failure diagnosis, system now fully operational with a water purity of 18.2 mega ohms.

Suez laboratory water leak

IMG_6816 IMG_6816 Client contacted Cryomed scientific when a leak appeared on their suez laboratory ultra pure water system , our engineer quickly pinpointed the issue, removed and replaced leaking fitting and had the system fully back operational within the hour.

Ultra pure water system service and validation

Annual service, calibration and validation of our clients triple red laboratory ultra pure water system.

IQ,OQ,PQ Validation of a new research facility

Panasonic blood fridge service and calibration

6 monthly service and calibration of our clients Panasonic blood fridge chart recorder and temperature display of upper and lower temperature readings

PHCBI Co2 incubator with co2 leakage fault

Customer called Cryomed scientific when they discovered their phcbi co2 incubators using excessive amounts of co2 , on arrival our incubator specialist engineer quickly diagnosed the fault and rectified the faults and having the incubators fully operational on the first visit

Helmer cooled incubator service and calibration

6 monthly service and calibration of our clients Helmer cooled incubator

Eppendorf laboratory co2 incubator fault

Client reported to Cryomed scientific an issue with their Eppendorf co2 incubator, Cryomed scientifics engineer quickly diagnosed the fault as the incubator control sensor, once the new temperature sensor was received from Eppendorf the sensor was removed and replaced, calibrated and the Eppendorf co2 incubator was back fully operational

Rephile RO Water purification system installation

Cryomed scientific supplied and installed a new Raphile laboratory RO water system to our clients laboratory, installed, calibrated and fully operational in 4 hours

Elga laboratory ultra pure water system service

New client contacted Cryomed scientific when their Elga ultra pure laboratory water system wasn’t achieving 18.2 mega ohms, our engineer quickly diagnosed that the RO membranes required replacing and the system required a full service and calibration , RO membranes replaced and annual service of the Elga ultra pure water system left the system fully… Continue reading Elga laboratory ultra pure water system service

Panasonic -150 Freezer leak and pressure test of 2nd stage system

A new client contacted Cryomed scientific when they found their Panasonic -150 ultra low freezer had failed, We uplifted the freezer back to our workshop when our engineer discovered the 2nd stage system of the Panasonic-150 freezer to have lost all its refrigerant charge. Once the Panasonic -150 freezer arrived at the workshop our engineers… Continue reading Panasonic -150 Freezer leak and pressure test of 2nd stage system

Statebourne liquid nitrogen system servicing

Annual servicing of our clients Statebourne liquid nitrogen systems , fully calibrated and serviced within one day

Hoshizaki laboratory Ice flaker repairs

Customer contacted Cryomed scientific to resolve issues with 2 hoshizaki laboratory ice flaker machines in their labs, both hoshizaki machines were in desperate need of a full service and replacement condenser fan motors , both motors replaced and both hoshizaki laboratory ice flaker machines serviced on the first visit and fully back in operation, happy… Continue reading Hoshizaki laboratory Ice flaker repairs

Infors shaker refrigerated incubators

Repairs of our customers refrigeration system on their infors refrigerated shaker incubator , also our engineer replaced the platelet actuator arms

Eppendorf -80 ult freezer door vacuum release issue

Customer called Cryomed scientific when they couldn’t open the outer freezer door to access their samples due to the door being jammed closed, Our engineer quickly diagnosed the issue as being an ice build up on the inner door over the vacuum release system, once the ice was removed the door was now easily opened… Continue reading Eppendorf -80 ult freezer door vacuum release issue

Purite ultra pure laboratory water system leak

IMG_5870 Client called Cryomed scientific when their Purite water purification system starting leaking , on closer investigation from our engineer he traced the leak to a faulty inlet water pressure guage, our water specialist quickly removed and replaced the leaking water pressure guage with a new one and the Purite ultra pure water system was… Continue reading Purite ultra pure laboratory water system leak

HAIER AND LABCOLD ULT -80 FREEZER SERVICING AND CALIBRATION

Annual service and calibration for our clients Haier and Labcold -80 ultra low temperature freezers

Millipore Ultra pure Laboratory water system fault

A call from our client regards flow issues with their Millipore laboratory ultra pure water system , our engineer quickly diagnosed the issue as being a failure of the flow meter on the Millipore system, removal and replacement of the flow meter quickly resolved the issue and the system was placed back into full operation.

Hot Room over temperature issue

Our client called Cryomed scientific to investigate an issue with over heating on a constant temperature hot room, on investigation of the temperature controller our engineer found the controller to be faulty and operating the heaters at 2 degrees above set point, After close discussions with our client our engineer removed and replaced the temperature… Continue reading Hot Room over temperature issue

Triple Red Avidity Science ultra pure water system fault

client called Cryomed scientific to report quality issues with the triple red Avidity science ultra pure water system, our engineer quickly diagnosed the fault as the quality sensor who then removed and replaced the sensor, calibrated the water quality by using our ultra pure water quality meter and retuned system to service

Coldroom compressor change

Customer complained that there was an unusual noise coming from the condensing unit that serves several coldrooms , our engineer quickly diagnosed the fault as the electronic Copeland compressor was running but not cooling, within 48 hours we had quoted the client , ordered and installed the new compressor with minimum down time to our… Continue reading Coldroom compressor change

CRYOMED SCIENTIFIC UKAS ISO 9001 ACCREDITATION

Cryomed Scientific are please to announce their annual ISO9001 accreditation has been awarded for 2024 with no non conformances , well done to all staff and Accendo consultants who perform our external audits.

Heraeus co2 incubator fan motor replacement

Customer contacted Cryomed Scientific when their Heraeus co2 incubator started fluctuating the co2 levels on the display and alarming, our engineer quickly assessed the issue as the internal fan motor seizure, after discussions with the department we then ordered and replaced the fan motor , fully calibrated co2 and temperature displays and left the incubator… Continue reading Heraeus co2 incubator fan motor replacement

Nuaire co2 incubators repaired,serviced and calibrated

Customer decided to move from Avidity to Cryomed Scientific to repair, service and calibrate their co2 incubators. Removal and replacement of air pump cured their issue with irratic c02 levels on one incubator,both incubators had their air, co2 and hepa filters removed and replaced, calibration performed by our Gemtech analyser, happy customer and over £2,000… Continue reading Nuaire co2 incubators repaired,serviced and calibrated

New Brunswick Scientific ULT -80 freezer servicing and calibration

Annual service and calibration of Cryomed scientific’s client New Brunswick -80 upright freezers, our engineer identified 2 faulty alarm batteries and a faulty control board which was causing the compressors to short cycle intermittently, not an easy fault find.IMG_5282

Ultra low temperature -80 freezers serviced and calibrated

Annual service and calibration of our clients 13 ultra low temperature -80 freezers

Panasonic ULT freezer 2nd stage compressor replacement

Panasonic -80 freezer 2nd stage compressor removal and replacement, full vacuum and pressure test of system and back down to -80 and ready for use once again within 24 hours

Fisher Scientific Basic co2 Incubator installation and service

Installation and Calibration of a new Fisher basic co2 incubator for our client

PANASONIC -150 ULTRA LOW TEMPERATURE FREEZER FAN MOTOR REPLACEMENT AND TIMER RESET

Customer called Cryomed scientific when there was a noise coming from their Panasonic -150 freezer and an alarm was indicated, our engineer quickly diagnosed the fault as a faulty condenser fan motor which was removed and replaced within the hour, master reset of alarm timers and freezer was back fully operational and operating at -150… Continue reading PANASONIC -150 ULTRA LOW TEMPERATURE FREEZER FAN MOTOR REPLACEMENT AND TIMER RESET

Panasonic co2 incubator leak

Customer called Cryomed scientific when they realised they were using too much co2 and the co2 incubator wasn’t achieving set point of 5% Our engineer quickly diagnosed and located the faulty burst tubing in the back of the co2 incubator, repaired and customer was back operational within a couple of hours.

Panasonic ult chest freezer compressor failure

Thermo scientific replacement ultra pure filter on our clients laboratory water purification system

Infors cooled incubator shaker repair

Removal and replacement of internal air circulating fan motors and control board on our clients infors cooled incubator shaker system

BINDER CO2 INCUBATOR FAULTS

IMG_4947A new client of Cryomed scientific contracted our service and validation department to install and commission their newly acquired binder co2 incubator, once fully operational and found to have passed our onsite calibration it was found the temperature controller was faulty and causing the heater system to keep heating until the safety switch activated and… Continue reading BINDER CO2 INCUBATOR FAULTS

New Brunswick ult freezer failure

SANYO ULT freezer 2nd stage system choking

Customer reported freezer fluctuating in temperature, on investigation by our ULT freezer engineer it was quickly diagnosed the 2nd stage refrigeration system was partially choking, removal and installation of a new filter drier on the 2nd stage refrigeration system cured the fault, freezer fully back operational and another happy customer.

Panasonic Blood fridge service and calibration

Fan motor replacement on Heraeus -80 chest freezer

Customer called Cryomed scientific due to thei Heraeus ultra low temperature freezer overheating, our engineer quickly identified the condenser fan motor to be faulty, due to our large stock of ult freezer parts our engineer replaced the fan motor and had the freezer fully operational and back down to -80 within the hour.

Avidity laboratory water system pump replacement

Customer contacted Cryomed scientific when they had a water leak from their Avidity science water purification system, our engineer quickly diagnosed the fault as the pump head leaking, pump was removed and replaced with system back fully operational.

Eppendorf replacement condenser fan motor

A new customer contacted Cryomed scientific when their Eppendorf -80 freezer broke down , our engineer attended site and replaced the condenser fan motor on the 1st visit as we carry a fully comprehensive parts list for all -80 freezers, freezer fully operational and back down to -80 before the end of the day, ready… Continue reading Eppendorf replacement condenser fan motor

Avidity water purification service and calibration

Annual service, calibration and validation of our customers Avidity ultra pure laboratory water purification system, all consumables supplied by Cryomed scientific, 18.2 m/ohms calibration completed with our calibration meter, temperature and time calibrated with our UKAS certified equipment.

Service and calibration of Binder co2 and O2 controlled incubator

Annual service and calibration of Binder co2, oxygen level and temperature control levels

Water pump repair to Elga ring main water purification system

University customer called Cryomed scientific when their Elga water purification ring main system stopped filling the reservoir tank and the system was leaking, Within an hour our engineer had removed the pump , repaired the leak and freed the seized pump, system back fully operation with minimum downtime for our client

RS BIOTECH EX DEMO ULT FREEZER DELIVERY

Another delivery and installation of our stock ult freezers, This one is an rs biotech badged New Brunswick-80 upright freezer that was purchased by Newcastle university just before the Christmas break, All our ex-demo and refurbished-80 freezers come complete with 12 month parts and labour warranty, fully serviced, calibration certification and temperature mapping if requested.… Continue reading RS BIOTECH EX DEMO ULT FREEZER DELIVERY

Used ult freezers for sale

Cryomed scientific have now taken stock of ult -86 freezers and these shall appear on our web site for sale at massively reduced prices from new, Featuring all the freezers manufacturers such as EPPINDORF,THERMO,PHCBI,SANYO,PANASONIC All freezers are supplied with 12 months parts and labour warranty, free delivery, calibration certificate,24 hour temperature map as standard. All… Continue reading Used ult freezers for sale

LEEC WARMING CABINET REPAIR

Customer contacted Cryomed scientific when two of her LEEC warming cabinets stopped operating and over heating,after diagnosing the fault on the phone to our customer as faulty control thermostats we dispatched our engineer,once on site both thermostats were replaced at the same visit due to a stock of parts for the LEEC warming cabinets, Within… Continue reading LEEC WARMING CABINET REPAIR

Annual service,calibration and validation of Millipore ultra pure integral 15 water purification system with A10 UV

An Annual service, calibration and validation of our clients ultra pure laboratory water system Millipore integral 15 with A10 uv Removal and replacement of all consumables supplied by Cryomed scientific cheaper than Millipore , replacement of RO membranes complete sanatisation of tank , all completed in one visit and customers system back fully operational operating… Continue reading Annual service,calibration and validation of Millipore ultra pure integral 15 water purification system with A10 UV

Annual service and Calibration of Leica cryostat

Customer contacted Cryomed scientific when their cryostat started showing ‘help’ on display, after servicing , calibration and reset of the help display cryostat is now back fully operational and operating at -25

Triple red’s SG ultra pure laboratory water system annual service and calibration to 18.2 m /ohms

Annual service and calibration of our customers Triple red / SG Ultra pure laboratory water purification system calibrated to 18.2 m/ohms, sanitisation of water storage tank and flushed to drain in the same day , fully back operational for our customer to use

Elga laboratory water purification system annual service and calibration to 18.2 m/ohms

The annual service and calibration of our customers Elga centra 200 laboratory ring main water purification system, consumables all changed sanitised and flushed to drain all within the same day , fully operational again for our customer to use with water quality at 18.2 m/ohms

-86 Ultra Low Temperature freezer servicing

An annual Panasonic and Gram bioline -80 freezer servicing and calibration, mobile ult freezer .

Avidity water system repair

Customer called Cryomed scientific when the manufacturer was unable to locate and repair water leak on the pure water system, within the hour our engineer located and replaced leaking part, System back fully operational and customer has asked for quotation to contract Cryomed scientific with all their water purification systems.

Annual -80 freezer servicing

Annual -80 freezer serving and calibration on these Eppendorf and Panasonic upright -80 freezers for our customer in Newcastle university

CBS PANASONIC LN2 VALIDATION

Cryomed scientific was contracted to perform the installation qualification and operational validation for their liquid nitrogen storage facility bank , 4 Panasonic CBS liquid nitrogen storage vessels validated and ready for performance validation in two days.

Oil separator removed and replaced on 2nd stage system of Thermo -80 ult freezer

New customer asked Cryomed scientific to diagnose the intermittent fault on their Thermo -80 upright ult freezer, freezer operating at -80 on arrival but after looking at temperature graphs it was easy to diagnose the intermittent failure of the 2nd stage refrigeration systems oil separator, Post ordering a replacement oil separator our engineer removed faulty… Continue reading Oil separator removed and replaced on 2nd stage system of Thermo -80 ult freezer

Annual service and calibration of laboratory fridges and freezers

Pleased to perform another annual service and calibration to our long standing client in edinburgh, Fridges and freezers serviced and single point calibration to traceable UKAS standards

-80 ULTRA LOW TEMPERATURE PANASONIC AND EPPENDORF FREEZER SERVICING AND CALIBRATION

Annual calibration and servicing of 2 -86 ult freezers for our client , Panasonic ult freezer and Eppendorf ult freezer, full calibration of the 20 comark temperature sensors of their monitoring system

Avidity Laboratory water system service and calibration

Annual service and calibration of Avidity ultra pure laboratory water system, consumables all replaced and timers reset, back in operation within a couple of hours, calibration completed to national standards